I've been trying to swap out a dead computer that operates a scale but the scale software is a pain in the ass. What have you guys been up to?

you are viewing a single comment's thread
view the rest of the comments
[-] TORFdot0@lemmy.world 1 points 1 year ago

Last month we had a failover cluster that we had to upgrade from 2012 R2 to 2016. Ever since the upgrade the storage performance (connected to a SAN via iSCSI) had tanked and backups were basically causing the whole house of cards to tumble.

Eventually found that the MPIO policy on the cluster disk had been reset by the in-place upgrade (bad practice to upgrade in place I know but we are a small shop and I don’t exactly have the time to rebuild another cluster from scratch)