76
you are viewing a single comment's thread
view the rest of the comments
view the rest of the comments
this post was submitted on 28 Nov 2024
76 points (100.0% liked)
Asklemmy
43995 readers
1067 users here now
A loosely moderated place to ask open-ended questions
If your post meets the following criteria, it's welcome here!
- Open-ended question
- Not offensive: at this point, we do not have the bandwidth to moderate overtly political discussions. Assume best intent and be excellent to each other.
- Not regarding using or support for Lemmy: context, see the list of support communities and tools for finding communities below
- Not ad nauseam inducing: please make sure it is a question that would be new to most members
- An actual topic of discussion
Looking for support?
Looking for a community?
- Lemmyverse: community search
- sub.rehab: maps old subreddits to fediverse options, marks official as such
- !lemmy411@lemmy.ca: a community for finding communities
~Icon~ ~by~ ~@Double_A@discuss.tchncs.de~
founded 5 years ago
MODERATORS
What kind of heating element did you use for the water? What type of control system to send power to it?
I'm using 220V/6kW heating element. When used with 60VDC directly from the panels, it's about 0,45kW. No need for control system, since that is too weak to bring the water to boil. It's function is just to decrease the consumption of heating oil. Oil burner is set to start at eavening just before enyone needs hot water and panel output goes down. Oil burner heats the water in the tank to 80ºC. It's about 40-60ºC next morning when the sun rises, depending on the consumption.
Did you manually switch it on once your battery storage was full?
At first yes, and I was planning to put raspberry + HAL-sensor + relay to handle the switch when average current to the batteries lowered, but to my surprise batteries charged enough with both connected. Battery charge controller is right next to the panels and there is some distance to the heating element. It appears that the MPPT battery charge controller so much lower resistance path that the current favors it.
My test setup only has 300Ah of battery, capacity at 12V, so it's charged quite quickly. Battery power only runs living room devices 50" TV, monitor, laptop, steamdeck, cable modem that are used about 4-6h a day and rarely on at the same time.
If it's a hot summers day, I might manually direct all to AC
... or if there's some catastrophic blackout during winter I can connect batteries to a radiator water circulation pump and heat the home by burning wood. This is very improbable, but at least there's something.
That sounds awesome. There seems to be a bit of a gulf in investment between getting a few panels to charge a backup battery or run some devices while camping, and actually doing a proper home integration. I'm in the midst of that gulf where I can generate more than I can easily store and use later, so I'd like to find some worthwhile uses for direct use of solar energy.
Don't know if you've seen it before, but here's an interesting article about direct solar.
https://solar.lowtechmagazine.com/2023/08/direct-solar-power-off-grid-without-batteries/